Output format
Tclk
Tclklo
Tsu
Thold
Data 0
Data 1
Clock
The Clock period (Tclk) is variable and will depend on the speed that the user card is swiped through the reader.
Data period (Tclk) = > 60 µs but < 3000 µs
Data Hold Time (Thold) = Tclk - Tclklo
Data Set-up Time (Tsu) = Tsu = Tclklo
Data Clock Low (Tclklo). This is ‘data dependent’ but will approximate to the following:
If Data = 0 (High) then Tclklo = Tclk / 2
If Data = 1 (Low) then Tclklo = Tclk / 3
The following diagram applies to all readers with serial number greater than or equal to 090008
Readers can be extended using Belden CR9540 10-core overall screened cable to a maximum of 100 metres.
Cable extensions
Voltage
Clock and data bit period
Reader head life
-20 °C +55 °C
5 metres
IPX7
1,000,000
8V DC 14V DC
90 mA 110 mA
60 µs 3000 µs
125 mm/s 1250 mm/s
500 mm/s
2
300 Oe 4000 Oe
34 mm 89 mm
34 mm
Specications
Electrical
Environment
Dimensions
Min
Max
Width
Height
Depth
Current
Operating temperature
Cable length
Reader
IP Rating
Outdoor Use
Swipes
Media speed
Media acceleration
Magnetic stripe coercivity